Sellingsgrove Foundation Repair

Category:

Date: 9/1/2019

 

The side of a home was settling and all of the tell tale signs were evident including cracks in the walls and trouble opening and closing doors and windows. The least invasive solution was helical piers.

Project Summary:

  • Helical Pile Type: RS2875.203
  • # of Helical Piles: 5
  • Location: Sellingsgrove, PA
  • Installation Depth: 12′ to 15′
  • Ultimate Pile Capacity: 20 kips
  • Equipment Used: Takeuchi TB140 Excavator, 12K Drive, Marian Torque Indicator