Helical Piles were installed to support a residential pool.
Project Summary:
- Helical Pile Type: 2875″.203
- # of Helical Piles: 26
- Location: Fayetteville, PA
- Installation Depth: 25′ – 35′
- Equipment Used: Skid Steer with a 12K drive head & Marian Torque Indicator
- Challenge/Unique Aspect: Due to soft clay soil, a deep foundation was required. In addition, the proximity to the house required a no vibration piling system and helicals achieved both objectives in a cost effective manner.
- General Contractor: Flohr Pools