A High Rise Public Housing Apartment Building in New York was adding an equipment pad for a pneumatic collection system. Helicals were selected to deal with unstable soils and as the least intrusive, neighbor friendly, deep foundation option.

Project Summary:

  • Helical Pile Type: IDEAL 3.5″ Pipe Piles
  • # of Helical Piles: 91
  • Location: New York, NY
  • Installation Depth: Avg. 45′
  • Helix Plates/Ultimate Pile Capacity: 8″10″12″ – 60 K DL Compression
  • Equipment Used: Excavator with Prodig 20K Drivehead
  • Challenge/Unique Aspect: The building was fully occupied so the work needed to proceed with minimal disturbance to Apartment dwellers; no vibration, limited noise or inconvience was allowed.
  • Danbro Installer: Navillus Inc.
  • Engineer/Architect:
    Steve Gencorrelli – Pile Design
    Dewberry MARVEL – Engineer of Record
  • General Contractor: Navillus Inc, for the New York City Housing Authority