124 Withers

A new four-story high rise was being constructed in Brooklyn (Williamsburg section). Historically Poor Soils would not allow for a slab on grade building. Driven piles were not allowed due to the close proximity of neighboring homes. Helical piles provided a no vibration, low impact, neighbor friendly, deep foundation solution.

Project Summary:

  • Helical Pile Type: Grouted Helical Micropile RS3500.300 with a 10″ grout column
  • # of Helical Piles: 86
  • Location: Williamsburg, NY
  • Installation Depth: 60′ to 85′
  • Ultimate Pile Capacity: 120 kips (12,000 Ft. lbs. torque)
  • Equipment Used: Cat 320, 30K Drive, Digital Torque Indicator
  • Challenge/Unique Aspect: The engineer of record requested a grout column to stiffen the pile in the low blow count, contaminated soil. DANBRO, with the aid and assistance of the IDEAL Group, designed a 10″ digger plate that pulled a 10″ grout column down around 3.5″ pipe pile to deal with lateral and corrosion concerns.
  • General Contractor: Izzo Builders