Avalon Fire Station Expansion – Load Test

The municipality of Avalon was expanding its Fire Station and a deep foundation was required. A load test was performed to determine the best helical configuration to achieve capacity at the shallowest depth.

Project Summary:

  • Helical Pile Type: 3″ Pipe Pile
  • # of Helical Piles: 4
  • Location: Avalon, NJ
  • Helix Plates/Ultimate Pile Capacity: 10″12″14″
  • Equipment Used: John Deer 35 Mini-Excavator with a 7.5 K Pro Dig drivehead
  • Challenge/Unique Aspect: The proximity of other municipal buildings in the complex required a no-vibration, non-invasive piling system. Several helical piles with different size plates were tested to arrive at the most effective/economical pile.
  • Danbro Installer: Titan Shoring & Construction LLC
  • Engineer/Architect: Mott MacDonald
  • General Contractor: OGREN Construction